Activate Your Remote Monitoring & Alarm System with the Most User-friendly Ethernet I/O
Developed with remote monitoring and alarm applications in mind, Moxa's Active Ethernet I/O comes with an array of features that make installing remote alarms friendly and easy. These functions are designed to reduce the effort required for configuration, maintenance, and troubleshooting. With Moxa's Active Ethernet I/O solutions, configuring an intelligent remote monitoring and alarm system can be done intuitively with a few clicks of the mouse.
Configuration is easy with Click&Go logic
Easy Integration with Different Software Platforms
LCD module for PC-free on-site management
Configuration is easy with Click&Go logic Active Ethernet I/O can be used to configure several input signals to act as a single event that can simultaneously trigger a network message and local output signals. People who understand basic If-Then-Else statements will instantly understand the Click&Go interface.
Versatile event collection and handling Moxa offers different libraries based on Windows and Linux platforms to assist IT engineers with integrating I/O signals to an IT system. In addition, ioLogik also supports SNMP allow SNMP-based software to get and set I/O status. Moxa's Active Ethernet I/O offers a variety of methods for event communication
Read or write I/O status with SNMP V.2
Support SNMP Trap for I/O status
Easy to integrate with existing SNMP software using MIB files
Free Windows .NET, VB and Windows/WinCE/Linux C API
CGI Command for web-base AP
Active OPC Server for SCADA systems
LCD module for PC-free on-site management Moxa's Active Ethernet I/O provides an optional LCD module for efficient on-site management and configuration. This unique display module can display both network and I/O settings. You can change network settings to ensure a speedy installation and easy future maintenance.
User-defined content for active I/O messaging Click&Go logic uses report by exception alarm method enables real-time alarm. Network messages are completely user-defined and can be configured for transmission when specific input signals are received. Messages can be customized with dynamic fields that indicate the exact time, date, or IP address of the I/O.
Perfect Mixture of Simplicity and Reliability for Remote Monitoring & Alarm Systems
IT-friendly Communications
IA-robust Reliability
Event Reaction Handling
Active Alarm: By e-mail/SNMP Trap/TCP/UDP
Active Message: By TCP/UDP socket, email, SNMP Trap
Polling of IO status : Modbus/TCP, SNMP
Flexible Configuration
Web console, Windows Utility
Real Time Information Recording
Using SNTP & built-in real time clock for data real-time stamp
Connection to SCADA
Active OPC server (coming soon in Q3, 2008)
Custom SCADA: By Lib. for Windows, CE, Linux. VB or VC
Built-in Watch Dog Timer
Hardware: Reboot the system
Software: Change to safe mode if connection failed